Hey, so what rs232/com settings should I be setting on this NCR7878
getting part of the barcode as ? instead of letters or zeros
danry25 @danry25 looks
danry25
@danry25
Jul 29 2016 11:13
hmm, seems to match the settings I have
danry25
@danry25
Jul 29 2016 11:39
So I directly attached to the serial port via sudo screen /dev/ttyS0 9600,cs7,ixon and I'm getting barcodes with S08A prefixed properly (had to add a hex 53 prefix in NCR flash tool). Not sure why when I cat /dev/ttyS0 its putting ? where letters are and numbers 0 & 6, 9
danry25
@danry25
Jul 29 2016 12:06
hmm
now when I cat /dev/ttyS0 I get xS08A<insertUPChere> or ~S08A<insertUPChere>
Cursor is hovering on the S, so I think I'm good to go?
should test after sleep
Andy Theuninck
@gohanman
Jul 29 2016 12:10
Sounds that way. As long as you have the carriage return ETX byte, pos.exe -v should list every message received from the scale
danry25
@danry25
Jul 29 2016 12:12
yeah, it is sending a carriage return
I guess onto figuring out the weight commands
Andy Theuninck
@gohanman
Jul 29 2016 16:14
There are two POS => scale commands. "S11" is get next stable non-zero weight and "S14" is get current status. The response to "S11" is "S11WWWW" where WWWW is the weight in hundreths of pounds. Responses to "S14" are "S140" for scale not ready, "S141" for scale in motion, "S142" for weight exceeding maximum, "S143" for stable zero weight, "S144WWWW" for stable non-zero weight, and "S145" for weight below zero.
danry25
@danry25
Jul 29 2016 19:41