These are chat archives for atomix/atomix

24th
Jul 2016
Mikhail
@middlesphere
Jul 24 2016 20:22
hi there! What is correct way to shutdown (disconnect) replica from cluster? method .leave or .shutdown ?
Jordan Halterman
@kuujo
Jul 24 2016 20:23
shutdown terminates the replica without removing it from the cluster and thus without affecting the quorum size. leave will remove the replica from the cluster, decreasing the quorum size
Mikhail
@middlesphere
Jul 24 2016 20:25
thanks.
can atomix pass jepsen tests?
Jordan Halterman
@kuujo
Jul 24 2016 20:28
yeah… they’re here and @jhalterman is working on improving them some more. Current tests are against simple data structures but pass for all types of partitions - bridge, isolated node, random halves, majorities ring, crashing a random subset
Mikhail
@middlesphere
Jul 24 2016 20:29
cool