Jun 17 2018 00:38 UTC
I need to delete log files as there is no space left on disk. What is the command to delete files?
Scott Leibrand
@scottleibrand
Jun 17 2018 01:15 UTC
Search the openaps docs, there’s a page on that.
schu4087
@schu4087
Jun 17 2018 01:16 UTC
I couldn't see it anywhere but a friend said it is 'rm'?
I think I have managed to delete some files...
Hey, is it significant that setup.sh is now showing --enable=' autotune ' with spaces before and after the quotes? (0.6.2-dev)
Dana Lewis
@danamlewis
Jun 17 2018 01:35 UTC
Autotune has been on by default in The last several versions
loztblaz
@loztblaz
Jun 17 2018 01:54 UTC
@ElwinABC I just encountered that as well, which led me here. The issue seems to be with the nodejs-legacy package in the install script, if you're seeing "E: Package 'nodejs-legacy' has no installation candidate" at the end of your error message.
Martin Haeberli
@mhaeberli
Jun 17 2018 04:16 UTC
for OpenAPS, master looks to be 0.6.1. on Edison, is it worth updating to dev (I assume this is 0.6.2) for slightly bleeding-edge production ?
Dana Lewis
@danamlewis
Jun 17 2018 05:28 UTC
Your call. We are close to releasing 0.6.2
j4cbo
@j4cbo
Jun 17 2018 05:44 UTC
apparently xeris pharmaceuticals (glucagon pen) is IPOing this week
loztblaz
@loztblaz
Jun 17 2018 06:28 UTC
I checked the docs but didn't see this edge case directly addressed. Does anyone have experience, or input, on how Regular insulin would perform with OpenAPS? I've got pretty high insulin resistance, to the point where I need to use U-500 insulin to not hit maximum bolus limits (or have to change a reservoir more than every day). It's only available as regular, not any of the rapid types. I'm coming from a 670g that clearly expects a rapid type insulin and would stack up microboluses until I crashed overnight. Increasing it's active insulin setting would just make it unable to combat slow rises. Would the bilinear curve handle this, given a generous enough "dia" setting?
skubesch
@skubesch
Jun 17 2018 08:44 UTC

Any suggestions on this JSON value error? This is a raspberry pi rig (old style with TI stick, no HAT):

Could not parse input data: [SyntaxError: /home/pi/myopenaps/monitor/iob.json: Unexpected end of input]
Traceback (most recent call last):
File "/usr/local/bin/openaps-report", line 82, in <module>
app( )
File "/usr/local/lib/python2.7/dist-packages/openaps/cli/init.py", line 51, in call
self.run(self.args)
File "/usr/local/bin/openaps-report", line 75, in run
output = app(args, self)
File "/usr/local/lib/python2.7/dist-packages/openaps/cli/subcommand.py", line 52, in call
return self.method.main(args, app)
File "/usr/local/lib/python2.7/dist-packages/openaps/reports/invoke.py", line 48, in main
reporters.Reporter(report, device, task)(output)
File "/usr/local/lib/python2.7/dist-packages/openaps/reports/reporters/init.py", line 33, in call
self.blob = self.serialize(data)
File "/usr/local/lib/python2.7/dist-packages/openaps/reports/reporters/init.py", line 31, in serialize
return self.method.serialize(render(data), self)
File "/usr/local/lib/python2.7/dist-packages/openaps/vendors/process.py", line 56, in prerender_json
return json.loads(data)
File "/usr/lib/python2.7/json/init.py", line 338, in loads
return _default_decoder.decode(s)
File "/usr/lib/python2.7/json/decoder.py", line 366, in decode
obj, end = self.raw_decode(s, idx=_w(s, 0).end())
File "/usr/lib/python2.7/json/decoder.py", line 384, in raw_decode
raise ValueError("No JSON object could be decoded")
ValueError: No JSON object could be decoded
Unsuccessful supermicrobolus pump-loop at Sun 17 Jun 04:42:46 EDT 2018

Jens Heuschkel
@juehv
Jun 17 2018 11:12 UTC
@danamlewis @scottleibrand After running 0.6.2 with 754+enlite+pi0+carelink for around a day I can conclude its working as good as 0.6.1 for me. I had some issues with 0.6.1 when it's not connected to the internet it stops working after some time. I didn't investigate the problem yet and I didn't test with 0.6.2.
PS: no idea if this is the right channel to tell you beta-test results ...
Scott Leibrand
@scottleibrand
Jun 17 2018 15:15 UTC
Thanks @juehv. Can you please also note that in the 0.6.2 PR for the record?
@skubesch cat /home/pi/myopenaps/monitor/iob.json
@loztblaz A couple folks used regular human insulin successfully with OpenAPS back in the bilinear days with a high enough DIA setting. Not sure if the exponential curves would work better, if you changed the insulinPeakTime and insulinEndTime to their maximum values. Do you know from the PK/PD literature what the normal peak time of regular is?
loztblaz
@loztblaz
Jun 17 2018 15:25 UTC
@scottleibrand I don't have the info in front of me, but just knowing that it's been done successfully is enough to make me want to try it out, considering how low the barrier to entry is. The fact that I can... actually change settings with this is pretty attractive after a month of trying to make Medtronic's Auto-Mode work. Thanks.
Scott Leibrand
@scottleibrand
Jun 17 2018 15:32 UTC
And if the allowable ranges in the code for rapid-acting insulin don’t allow you to go long enough, you could pretty easily add support for a new insulin type there (probably call it “regular”) with more appropriate defaults and allowable ranges.
loztblaz
@loztblaz
Jun 17 2018 15:40 UTC
Fair point. Well, just made the jump and ordered the hardware, but also wanted to say I appreciate the heck out of everyone contributing to this (and other) community projects. Having options like OpenAPS when commercial products fall short of expectations gives me a lot of hope.
Scott Leibrand
@scottleibrand
Jun 17 2018 16:07 UTC
:+1: :-)
Jon Cluck
@cluckj
Jun 17 2018 16:09 UTC
:clap:
Dosefinder
@Dosefinder
Jun 17 2018 16:14 UTC
image.png
Hi all, My newly installed RPi 3 + Explorer hat running oref0 0.7 dev is not working proper with NS. It uploads IOB and pump data automatically but not basal. If I use "openaps upload" i will upload the lates basal to NS but only once. Do any one know how to fix this? Thank you in advance.
Scott Leibrand
@scottleibrand
Jun 17 2018 16:17 UTC
What do your logs say?
In particular the ns-loop.log for this kind of issue.
Dosefinder
@Dosefinder
Jun 17 2018 16:22 UTC
If it is this one: tail -F /var/log/openaps/ns-loop.log
It says:
Starting oref0-ns-loop at Sun 17 Jun 18:20:02 CEST 2018:
Found recent valid BG:
{"glucose":157,"dateString":"2018-06-17T18:17:28+02:00"}
Latest NS temptargets: Merging local temptargets: Temptargets merged: Refreshed carbhistory; COB: 0
No recent suggested.json found; last updated Jun 17 18:14
[{"duration":30,"raw_duration":{"timestamp":"2018-06-17T18:11:43+02:00","_type":"TempBasalDuration","duration (min)":30},"timestamp":"2018-06-17T18:11:43+02:00","absolute":1.85,"rate":1.85,"raw_rate":{"timestamp":"2018-06-17T18:11:43+02:00","_type":"TempBasal","temp":"absolute","rate":1.85},"eventType":"Temp Basal","medtronic":"mm://openaps/mm-format-ns-treatments/Temp Basal","created_at":"2018-06-17T18:11:43+02:00","enteredBy":"openaps://medtronic/","_id":"5b268a4036bc573b16021a90"}]
Completed oref0-ns-loop at Sun 17 Jun 18:20:16 CEST 2018
Scott Leibrand
@scottleibrand
Jun 17 2018 16:28 UTC
Looks to me like it just updated a new TempBasal record of 1.85U/h
Dosefinder
@Dosefinder
Jun 17 2018 16:39 UTC
Yes but i think that is because i used the command "openaps upload". In the screen on the Explorer hat shows TB: 30 1.5 U and IOB: 0.9 U and the new ns-loop.log says:
Starting oref0-ns-loop at Sun 17 Jun 18:38:01 CEST 2018:
Found recent valid BG:
{"glucose":156,"dateString":"2018-06-17T18:32:28+02:00"}
Latest NS temptargets: Merging local temptargets: Temptargets merged: Refreshed carbhistory; COB: 0
No recent suggested.json found; last updated Jun 17 18:14
No new treatments to upload
Completed oref0-ns-loop at Sun 17 Jun 18:38:14 CEST 2018
Jon Cluck
@cluckj
Jun 17 2018 16:42 UTC
Is that an edison-battery.json issue because it's a pi3?
skubesch
@skubesch
Jun 17 2018 16:42 UTC
Thank you @scottleibrand, that file is empty. I would be grateful for any ideas on next steps.
Dosefinder
@Dosefinder
Jun 17 2018 16:43 UTC
Yes it gets that issue in the "l" log: Could not parse edison-battery.json: [SyntaxError: Unexpected end of input]
/root/src/openaps-menu/scripts/status.js:103
var x = 2 + zero_x + Math.round(((((bg[i].date - zerotime)/1000)/60)/5));
Dosefinder
@Dosefinder
Jun 17 2018 17:15 UTC
@cluckj and @scottleibrand Thanks for your reply. I just runned the setup again. The rig is looping but still not uploading to NS. The ns-loop.log is saying: Starting oref0-ns-loop at Sun 17 Jun 19:11:02 CEST 2018:
Glucose file is fresh
{"glucose":157,"dateString":"2018-06-17T19:07:28+02:00"}
Latest NS temptargets: Merging local temptargets: Temptargets merged: Refreshed carbhistory; COB: 0
Couldn't generate ns-status.json
Is there a work around for this?
Scott Leibrand
@scottleibrand
Jun 17 2018 17:16 UTC
Does your rig have a battery?
Dosefinder
@Dosefinder
Jun 17 2018 17:19 UTC
It is plugged in to my PC and power from the PC, will it help to give it a battery?
Scott Leibrand
@scottleibrand
Jun 17 2018 17:33 UTC
Likely. It’s trying to detect the lipo battery voltage.
There’s a PR open to work around that, if you want to test it.
On the openaps-menu repo.
Scott Leibrand
@scottleibrand
Jun 17 2018 17:57 UTC
Not right now, I’m on my phone. Just look at the pull requests on the repo.
loztblaz
@loztblaz
Jun 17 2018 18:25 UTC
Not directly related to OpenAPS, but is anyone aware of community information on pump repair? My Paradigm 723 had the known issue of the motor pushing part of the casing out. I superglued it as a fix until I got a new pump, but if possible I'd like to properly repair it before starting OpenAPS.
Currently considering buying a higher firmware version of the same model and swapping parts around, but figured I'd ask.
Dana Lewis
@danamlewis
Jun 17 2018 18:41 UTC
I would advise against swapping parts
Saskia
@Missdazzle
Jun 17 2018 18:50 UTC
Somebody´s European Veo just died, I fear. Trying to rewind but then motor error alarm instead: motor error, insulin delivery stopped, disconnect pump site... Taking out the battery, and putting it back in after a while didn´t help. Any chance to bring the pump back to life? (This happened after trying to get the battery cap off which has been screwed in too hard.)
loztblaz
@loztblaz
Jun 17 2018 18:52 UTC
Agree part swapping isn't ideal, but I'm intending to only do plastic case parts, I suppose I wasn't clear about that.
Scott Leibrand
@scottleibrand
Jun 17 2018 18:54 UTC
Unfortunately the case is molded shut, so opening it is likely to break seals and risk causing delivery issues.
loztblaz
@loztblaz
Jun 17 2018 19:17 UTC
That's a good reason to not mess with it. Guess I'll start proactively watching for a replacement.
Martin Haeberli
@mhaeberli
Jun 17 2018 19:19 UTC
@danamlewis late :+1: thx on 0.6.2 beta status
kallnap
@kallnap
Jun 17 2018 19:28 UTC
I would be carefull, i do not know where the force sensor for occlusion detection is located in the medtronic pumps. It may push against the housing.
th122
@th122
Jun 17 2018 19:42 UTC
loztblaz
@loztblaz
Jun 17 2018 19:53 UTC
Yeah, I found that teardown, but both Dana and Scott seem to be correct here, seals and sensors would make it a bad idea unless I was scrapping it for science reasons.
Dosefinder
@Dosefinder
Jun 17 2018 20:07 UTC
@scottleibrand Since the RPI do not seem to have a '/root/src/EdisonVoltage/voltage'. I tried: openaps/oref0#751 but it seems as it is deleted (pathspec 'edisonvoltage-fix' did not match any file(s) known to git). Also tried placing fake data in monitor/edison-voltage.json (openaps/oref0#868). But it seems to get deleted every time the loop runs. So I guess I have to use a lipo battery.
Jon Cluck
@cluckj
Jun 17 2018 20:32 UTC
@jaylagorio I'm here too if you want live support :)
Jon Cluck
@cluckj
Jun 17 2018 20:38 UTC
@Dosefinder can you give this PR a try? openaps/openaps-menu#14
Dosefinder
@Dosefinder
Jun 17 2018 20:57 UTC
@cluckj
Thanks I Will look in to it tomorrow :)
Jon Cluck
@cluckj
Jun 17 2018 20:59 UTC
:thumbsup: